HCal is a simple calibration reminder tool. It is vendor-neutral and you can enter any piece of equipment from any manufacturer and track its calibration date and due date. At its core it's asset management software made simple. It doesn't matter if it's a multimeter, insulation tester, hi-pot, hot gloves, hot stick, ratchet, transmitter, torque wrench, thermometer, pressure gauge or anything else you can think of.

Key Features

  Manufacturer Model Serial # Internal Asset ID Cal Lab Asset ID Cal Date
(YYYY-MM-DD)
Due Date
(YYYY-MM-DD)
Days Left Additional Accessories Home Location Shelf Status
  AEMC 6240a 1012323FKDV WSH1234 R89767 2016-09-01 2020-06-01 -1703 In Shop In Shop In Service
  Crystal IS33 2262-384876 WSH0009 Y47487 2017-12-25 2018-12-25 -2226 Building 10 Factory In Service
  Doble M4100 78657 WSH0005 AHJG3899 2018-05-09 2020-06-01 -1703 In Office In Office A2 In Service
  Fluke 1630 WSH0019 Scrap Bin NFG
  Fluke 68 364848746 WSH0008 R4748 2016-12-25 2018-12-25 -2226 Heating Plant At Ace Labs B3 Sent for Calibration
  Fluke 721 Squish Toy None WSH0003 2017-01-09 2018-01-08 -2577 In Office In Office B4 In Service
  Fluke 87III 13748464 WSH0022 2017-11-14 2018-11-14 -2267 Mike Mike Scrap Bin NFG
  Fluke 87V 123897897 Bob 2017-09-01 2018-09-01 -2342 Warehouse Warehouse In Service
  Fluke 87V 897678667 Steve 2017-05-28 2018-05-28 -2438 Warehouse Warehouse Wet
  GPS Tracker SDF324234FDSF WSH0015 In Shop In Shop In Service
  HV Inc HVA60 234 WSH0017 F234543 2016-12-31 2017-12-31 -2585 At Site At Site FUBAR
  Mastercraft 1/2 Drive Ratchet None Truck 5678 Truck 5678 In Service
  Megger BITE 3 1475857575757 WSH0018 Scrap Bin NFG
  Megger MIT420 101374858 WSH0023 Y3748 2017-12-21 2018-12-21 -2230 At Ace Labs At Ace Labs Sent for Calibration
  Megger MIT525 10188746/38R786 WSH0004 64778 2016-12-25 2017-12-25 -2591 2 of 2 cases At site 435 At site 435 In Service
  Omicron CMC356 FE7658 WSH0012 T3246 2017-08-01 2018-08-01 -2373 2 boxes of leads 2 of 4 and 3 of 4 Omicron Factory Omicron Factory Factory Repair
  Pfisterer 10ft Ground Chain None WSH0010 TB12334 2016-02-04 2018-02-04 -2550 Hard Case Building 213 Building 213 Scrapped
  Rosemount 3051 FY678FHH78 DP-46-TL 2017-11-30 2018-11-30 -2251 Anzac Site 54 Anzac Site 54 In Service

Legend: Due within 30 Days Overdue